Description
Pressure booster pumps increase water pressure from city mains or private water
systems. Applications include providing high water pressure for washing buildings, dairy
walls or floors, hog parlors, poultry houses, rinsing or spray cooling equipment, lawn
sprinkling and insecticide spraying.
Single-phase models are equipped with a capacitor start, thermal protected motor.
Three-phase models require separate overload protection.
Unpacking
When unpacking the unit, inspect
carefully for any damage that may
have occurred during transit.
NOTE: Use pump with clear water
only.
132934 C
Pressure Booster Pumps
Operating Instructions & Parts Manual
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or prop-
erty damage! Retain instructions for future reference.
IL0391B
3.88
3.25 "C"
"F"
3.75
9.75
1-1/2 & 2HP 1Ø TEFC
ALL 3HP 1Ø
9.00
(MODELS WITH HANDLES)
6.50
7.15
4.88
TEFC ONLY
5.28
2 & 3HP
1Ø TEFC ONLY
1.44
"H" INLET
"J" DISCHARGE
Figure 1
Pump Dimensions 60 Hz Chart A
HP GPM Stage “C”
F
H J
F&W
TEFC
1 Phase 3 Phase
1/3 5 8 10.19 19.81 - - .75 .75
1/3* 5 8 10.19 20.06 22.04 - .75 .75
1/2 5 12 13.38 23.25 23.23 24.10 .75 .75
1/2* 5 14 14.97 25.34 26.82 25.69 .75 .75
3/4 5 16 16.54 26.91 28.77 27.51 .75 .75
3/4 7 12 13.38 23.75 25.61 24.35 .75 .75
3/4* 7 14 14.97 25.84 27.20 25.94 .75 .75
1 10 14 16.31 27.18 29.16 28.02 .75 .75
1-1/2 10 16 18.13 29.62 31.48 30.07 .75 .75
1* 10 20 21.69 33.18 34.54 33.40 .75 .75
1* 10 22 23.50 34.99 36.35 35.21 .75 .75
1* 10 23 24.38 35.87 37.73 36.09 .75 .75
2 19 14 17.89 29.88 32.12 30.87 .75 .75
1-1/2* 19 20 24.06 36.05 37.41 36.00 .75 .75
2* 19 22 26.13 38.12 40.36 39.11 .75 .75
2 27 11 15.38 27.37 29.61 28.36 1.00 1.00
3 27 14 18.50 30.49 33.85 33.35 1.00 1.00
2* 27 17 21.59 33.58 35.82 34.57 1.00 1.00
3 27 17 21.59 33.74 - - 1.00 1.00
2 35 6 13.94 25.93 28.17 26.92 1.00 1.00
3 35 8 17.13 29.12 32.48 31.98 1.00 1.00
1-1/2* 35 8 17.13 29.12 30.48 29.07 1.00 1.00
3* 35 14 26.86 38.85 42.21 41.71 1.00 1.00
Vista de página 0
1 2 3 4 5 6 ... 14 15

Resumo do Conteúdo

Página 1 - Pressure Booster Pumps

1Copyright © 2014 FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 flintandwalling.comDescriptionPressure booster pumps increase

Página 2 - 60Hz Models

10Copyright © 2014 FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 flintandwalling.comOperation (Continued)START - UP PROCEDURE

Página 3

11Copyright © 2014 FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 flintandwalling.comMaintenance (Continued) IMPORTANT: Do no

Página 4 - Pre-Installation

12Copyright © 2014 FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 flintandwalling.comTroubleshooting ChartSymptom Possible Cau

Página 5

13Copyright © 2014 FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 flintandwalling.comBooster Pump Parts DrawingFigure 20 - Car

Página 6 - Installation (Continued)

14Copyright © 2014 FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 flintandwalling.comFORM NO. FW00450813SUPERSEDES 0208IL05659

Página 7

15Copyright © 2014 FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 flintandwalling.comPRESSURE BOOSTER PUMP REPAIR PARTS(For Pr

Página 8

2Copyright © 2014 FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 flintandwalling.comSingle Phase Motor Data 60HZ

Página 9 - Operation

3Copyright © 2014 FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 flintandwalling.comThree Phase Motor Data

Página 10 - Maintenance

4Copyright © 2014 FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 flintandwalling.comGeneral Safety InformationCarefully read a

Página 11 - Maintenance (Continued)

5Copyright © 2014 FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 flintandwalling.comIL1014Mount pump in correct position or pu

Página 12 - Troubleshooting Chart

6Copyright © 2014 FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 flintandwalling.comInstallation (Continued)5. A pressure gau

Página 13 - Internal Parts Detail

7Copyright © 2014 FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 flintandwalling.comInstallation (Continued) Proper rotation o

Página 14 - Replacement Motors

8Copyright © 2014 FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 flintandwalling.comInstallation (Continued)IL1229654321789654

Página 15 - 60 HZ MODELS

9Copyright © 2014 FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 flintandwalling.comInstallation (Continued)5. Specific Wirin

Comentários a estes Manuais

Sem comentários